7-19
MFN HEATING NOZZLES
Propane Cubic
Feet per Hour
Oxygen Cubic
Feet per Hour
Tip
Size
Propane
Pressure
Range
(PSIG)
Oxygen
Pressure
Range
(PSIG)
Min Max Min Max
BTU per
Hour
8 10-15 10-20 10 35 40 140
See
Note,
page
23
10 12-20 10-30 20 80 80 320
12* 15 - 25 30 - 125 30 160 120 640
15* 15 - 25 30 - 125 50 200 200 800
20* 20 - 30 40 - 135 75 250 300 1000
*Use model HD310C torch and 3/8" hose.
TYPES 1-101, 3-101 (OXY-ACETYLENE)
Cutting Oxygen Acetylene
Metal
Thickness
Tip
Size
Pres
-
sure***
(PSIG)
Flow***
(SCFH)
Pre-heat
Oxygen*
(PSIG)
Pres-
sure
(PSIG)
Flow
(SCFH)
Speed
(IPM)
Kerf
Width
1/8" 000 20 - 25 20 - 25 3 - 5 3 - 5 6 - 11 20 - 30 .04
1/4" 00 20 - 25 30 - 35 3 - 5 3 - 5 6 - 11 20 - 28 .05
3/8" 0 25 - 30 55 - 60 3 - 5 3 - 5 6 - 11 18 - 26 .06
1/2" 0 30 - 35 60 - 65 3 - 6 3 - 5 9 - 16 16 - 22 .06
3/4" 1 30 - 35 80 - 85 4 - 7 3 - 5 8 - 13 15 - 20 .07
1" 2 35 - 40 140 - 160 4 - 8 3 - 6 10 - 18 13 - 18 .09
2" 3 40 - 45 210 - 240 5 - 10 4 - 8 14 -24 10 - 12 .11
3" 4 40 - 50 280 - 320 5 - 10 5 - 11 18 - 28 10 - 12 .12
4" 5 45 - 55 390 - 450 6 - 12 6 - 13 22 - 30 6 - 9 .15
6" 6** 45 - 55 500 - 600 6 - 15 8 - 14 25 - 35 4 - 7 .15
10" 7** 45 - 55 700 - 850 6 - 20 10 - 15 25 - 35 3 - 5 .34
12" 8** 45 - 55 900 - 1050 7 - 25 10 - 15 25 - 35 3 - 4 .41
* Applicable for three-hose machine cutting torches only. With a two-hose cuting torch,
preheat pressure is set by the cuttting oxygen.
** For best results use HC1200C series torches and 3/8" hose using a size 6 tip or
larger.
*** All pressures are measured at the regulator using 25' x 1/4" hose through tip size 5,
and 25' x 3/8" hose for tip size 6 and larger.
Komentarze do niniejszej Instrukcji