37.Verifyallconnectionsandttingsaresecure.
38.Verifytherearenotoolsorpiecesofsheetmetalorotherconductiveobjectsleftinthepowersupplyor
touching any part inside.
Checkforleaks
39. Reconnect the power once you have verified the last two steps and turn the system on.
40. If your coolant pump comes on, check for leaks and shut down immediately if you do until you can fix them.
If the pump does not come on for your model then check the operating sequence information in the operating
manual for your system to get the pump to circulate coolant.
41. Once you have determined there are no leaks, disconnect power and reinstall the side panels. Once the side
panels are back in place you can power up the unit and get back to cutting.