Manual 0-4825 Rev. AK 8-39 TORCH DATA for AutoCut Basic
Aluminum
300A
Air Plasma / Air Shield
Shield
Cap
Shield Gas
Distributor
Tip
35-1037 35-1283 35-1050
Plasma (Air) Shield (Air)
(ga) (in) inch (PSI) (PSI) Volts
(in)
±0.005
(ipm) (in) (sec) (in)
3/4 0.750 90 80 179 0.200 90 0.350 0.4 0.220
7/8 0.875 90 80 179 0.200 75 0.400 0.5 0.230
1 1.000 90 80 180 0.200 70 0.400 0.7 0.240
1.25 1.250 90 80 194 0.250 45 0.450 1.5 0.270
1.5 1.500 90 80 200 0.250 20 0.450 2.2 0.300
1.75 1.750 90 80 210 0.250 19 0.300
2 2.000 90 80 220 0.250 18 0.300
Plasma (Air) Shield (Air)
(Bar) (Bar) Volts
(mm)
±0.1
(mm/min) (mm) (sec) (mm)
6.2 5.5 179 5.1 2290 8.9 0.4 5.6
6.2 5.5 180 5.1 1780 10.2 0.7 6.1
6.2 5.5 192 6.4 1140 11.4 1.5 7.0
6.2 5.5 201 6.4 510 11.4 2.2 7.6
6.2 5.5 219 6.4 460 7.6
BOLD TYPE
indicates maximum piercing parameters.
BOLD ITALIC
indicates edge starts only.
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Kerf Width
@ Rec.
Speed
Material
Thickness
Cut Flow Rates /
Arc
Voltage
Torch
Working
Height
30
Material
Thickness
Cut Flow Rates /
Arc
Voltage
Torch
Working
Height
(mm)
20
25
Kerf Width
@ Rec.
Speed
Shield
Retainer
Plasma Gas
Distributor
Electrode Cartridge
35-1044 35-1088 35-102235-1021
50
Edge Start
Edge Start
Edge Start
40
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Cartridge
Electrode
Shield
Shield Gas
Distributor
Tip
Plasma Gas
Distributor
Shield Retainer
Art # A-07917_AC